{"id":20984,"date":"2022-02-01T11:05:11","date_gmt":"2022-02-01T08:05:11","guid":{"rendered":"http:\/\/skard.ru\/?post_type=product&#038;p=20984"},"modified":"2022-02-21T10:34:49","modified_gmt":"2022-02-21T07:34:49","slug":"aik-1-40b-antenna-measuring-kit-900-40000-mhz-kopirovat-6","status":"publish","type":"product","link":"https:\/\/skard.ru\/en\/product\/aik-1-40b-antenna-measuring-kit-900-40000-mhz-kopirovat-6\/","title":{"rendered":"AIK 1\u201340B\/06 antenna measuring kit 820\u201326,500 MHz"},"content":{"rendered":"<p>AIK 1-40B is a unique set of metrologically coordinated measuring instruments and auxiliary devices, which makes it possible to provide all the necessary options for constructing a measuring path, from a measuring antenna to the input of a spectrum analyzer, measuring receiver or other receiving measuring device.<\/p>\n<p>&nbsp;<\/p>\n<p>Features<\/p>\n<p>The kit is available in 11 modifications depending on the operating frequency range;<\/p>\n<p>Each measuring instrument from the kit (antennas, LNA, transducers, cable assemblies) is provided with calibration graphs;<\/p>\n<p>The kit is equipped with a large range of auxiliary devices for convenience and safety of use;<\/p>\n<p>According to the operating conditions, the kits belong to group 6 in accordance with GOST 22261-94.<\/p>\n<p>&nbsp;<\/p>\n<p>Kit modifications<\/p>\n<table>\n<tbody>\n<tr>\n<td width=\"213\">\n<p>No.<\/p>\n<\/td>\n<td width=\"213\">\n<p>Modification<\/p>\n<\/td>\n<td width=\"213\">\n<p>Operating frequency range<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>1<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/01<\/p>\n<\/td>\n<td width=\"213\">\n<p>0.9 to 40,0 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>2<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/02<\/p>\n<\/td>\n<td width=\"213\">\n<p>8.2 to 40.0 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>3<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/03<\/p>\n<\/td>\n<td width=\"213\">\n<p>18.0 to 40.0 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>4<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/04<\/p>\n<\/td>\n<td width=\"213\">\n<p>26.5 to 40.0 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>5<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/05<\/p>\n<\/td>\n<td width=\"213\">\n<p>0.9 to 26.5 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>6<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/06<\/p>\n<\/td>\n<td width=\"213\">\n<p>8.2 to 26.5 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>7<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/07<\/p>\n<\/td>\n<td width=\"213\">\n<p>18.0 to 26.5 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>8<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/08<\/p>\n<\/td>\n<td width=\"213\">\n<p>0.9 to 18.0 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>9<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/09<\/p>\n<\/td>\n<td width=\"213\">\n<p>8.2 to 18.0 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>10<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/10<\/p>\n<\/td>\n<td width=\"213\">\n<p>0.9 to 12.4 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td width=\"213\">\n<p>11<\/p>\n<\/td>\n<td width=\"213\">\n<p>AIK 1-40B\/11<\/p>\n<\/td>\n<td width=\"213\">\n<p>8.2 to 12.4 GHz<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n<p>KIT COMPOSITION<\/p>\n<p>Antennas:<\/p>\n<p>&#8211; P6-140-x &#8211; reconfigurable measuring horn antenna in the frequency range 8.2 \u00f7 40.0 GHz (detailed information on page 70 of the catalogue).<\/p>\n<p style=\"text-align: center;\"><a href=\"http:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-140-1_aik-1-40b.jpg\" data-rel=\"lightbox-image-0\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" class=\"alignnone wp-image-13562\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-140-1_aik-1-40b.jpg\" alt=\"\" width=\"250\" height=\"250\" \/><\/a><\/p>\n<p>Coaxial-to-waveguide transducers and waveguide transducers:<\/p>\n<p>&#8211; KVP0812 SF: coaxial-to-waveguide transducer from WR-90 waveguide to the coaxial one of type SMA (socket) in accordance with GOST RV 51914;<\/p>\n<p>&#8211; BC1218 SF: waveguide transducer from WR-90 to one-piece coaxial-waveguide transducer with SMA connector (socket);<\/p>\n<p>&#8211; BC1826 KF: waveguide transducer from WR-90 to one-piece coaxial-waveguide transducer with K connector (socket) (PS-2.92).<\/p>\n<p><img loading=\"lazy\" class=\" wp-image-21229 aligncenter\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2022\/02\/img_8915_04.png\" alt=\"\" width=\"155\" height=\"137\" \/> <img loading=\"lazy\" class=\" wp-image-21258 aligncenter\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2022\/02\/img_8937_03_small-1.jpg\" alt=\"\" width=\"213\" height=\"153\" \/> <img loading=\"lazy\" class=\" wp-image-21261 aligncenter\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2022\/02\/img_8928_02_small.jpg\" alt=\"\" width=\"280\" height=\"182\" \/><\/p>\n<p>&nbsp;<\/p>\n<p>Low noise amplifiers:<\/p>\n<p>\u2014 MM 0118. SFSF: low noise amplifier in the range of 0.9 \u00f7 18.0 GHz;<\/p>\n<p>\u2014 MM 1826. KFKF: low noise amplifier in the range of 18.0 \u00f7 26.5 GHz.<\/p>\n<p><img loading=\"lazy\" class=\" wp-image-21253 aligncenter\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2022\/02\/mshu_01_a-2.png\" alt=\"\" width=\"231\" height=\"143\" \/><\/p>\n<p>\u00a0<img loading=\"lazy\" class=\" wp-image-21265 aligncenter\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2022\/02\/mshu_1826.jpg\" alt=\"\" width=\"222\" height=\"157\" \/><\/p>\n<p>UHF transducers:<\/p>\n<p>\u2014 OP 0118. SMSM: SMA (m) &#8211; SMA (f) transducer in the range of 0.9 \u00f7 18.0 GHz;<\/p>\n<p>\u2014 MP 0118. NMSF: N (m) &#8211; SMA (f) transducer in the range of 0.9 \u00f7 18.0 GHz;<\/p>\n<p>\u2014 OP 1840. KMKM: K (m) &#8211; K (m) transducer in the range of 18.0 \u00f7 40.0 GHz.<\/p>\n<p><a href=\"http:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-123_aik-1-40b-10.jpg\" data-rel=\"lightbox-image-1\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" class=\"aligncenter wp-image-13581\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-123_aik-1-40b-10.jpg\" alt=\"\" width=\"521\" height=\"200\" srcset=\"https:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-123_aik-1-40b-10.jpg 685w, https:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-123_aik-1-40b-10-1x1.jpg 1w, https:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-123_aik-1-40b-10-10x4.jpg 10w, https:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-123_aik-1-40b-10-24x9.jpg 24w, https:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-123_aik-1-40b-10-36x14.jpg 36w, https:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/p6-123_aik-1-40b-10-48x18.jpg 48w\" sizes=\"(max-width: 521px) 100vw, 521px\" \/><\/a><\/p>\n<p>&nbsp;<\/p>\n<p>Measuring cables:<\/p>\n<p>\u2014 KI 0118. SMSM: measuring cable (1.5 m), 0.9 \u00f7 18.0 GHz range;<\/p>\n<p>\u2014 KI 1840. KMKM: measuring cable (1.2 m), 18.0 \u00f7 40.0 GHz range.<\/p>\n<p><a href=\"http:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/aik-1-40b-5.jpg\" data-rel=\"lightbox-image-2\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" class=\"aligncenter wp-image-13554\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/aik-1-40b-5.jpg\" alt=\"\" width=\"300\" height=\"300\" \/><\/a><\/p>\n<p>Accessory devices and options:<\/p>\n<p>\u2014 AK-02M: fitting for mounting the antenna to the universal photo tripod;<\/p>\n<p>\u2014 KZU-A: grounding device;<\/p>\n<p>\u2014 LNA power supply unit;<\/p>\n<p>\u2014 Hard case &#8220;Standard&#8221; or &#8220;Protection&#8221;*;<\/p>\n<p>\u2014 Wrench;<\/p>\n<p>\u2014 Flat-blade screwdriver;<\/p>\n<p>\u2014 Adjustment device (bore sighting tube);<\/p>\n<p>\u2014 Photo tripod *;<\/p>\n<p>\u2014 ShAD-01 dielectric tripod*;<\/p>\n<p>\u2014 Laser marker with mount fitting*.<\/p>\n<p>*optional devices (not included in the package).<\/p>\n<p><a href=\"http:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/aik-1-40b-4.jpg\" data-rel=\"lightbox-image-3\" data-rl_title=\"\" data-rl_caption=\"\" title=\"\"><img loading=\"lazy\" class=\"aligncenter wp-image-13556\" src=\"http:\/\/skard.ru\/wp-content\/uploads\/2021\/02\/aik-1-40b-4.jpg\" alt=\"\" width=\"350\" height=\"350\" \/><\/a><\/p>\n<p>Set of operational documents:<\/p>\n<p>\u2014 Test methods;<\/p>\n<p>\u2014 Operation manual;<\/p>\n<p>\u2014 Logbook;<\/p>\n<p>\u2014 Album of charts;<\/p>\n<p>\u2014 Materials consumption rates.<\/p>\n<p>Note: the list &#8220;Kit Composition&#8221; contains the full range of measuring instruments, auxiliary devices and options for all modifications of the kit.<\/p>\n<p>&nbsp;<\/p>\n<p>&nbsp;<\/p>\n","protected":false},"excerpt":{"rendered":"<p>&nbsp;<\/p>\n<table>\n<tbody>\n<tr>\n<td style=\"background-color: #009fe3; color: #ffffff;\" colspan=\"2\">\n<p style=\"text-align: center;\">Specifications<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Frequency range<\/p>\n<\/td>\n<td>\n<p>820 MHz &#8211; 26.5 GHz<\/p>\n<\/td>\n<\/tr>\n<tr>\n<td>\n<p>Polarization<\/p>\n<\/td>\n<td>\n<p>Linear<\/p>\n<\/td>\n<\/tr>\n<\/tbody>\n<\/table>\n","protected":false},"featured_media":20986,"template":"","meta":[],"etheme_brands":{"errors":{"invalid_taxonomy":["Invalid taxonomy."]},"error_data":[]},"_links":{"self":[{"href":"https:\/\/skard.ru\/en\/wp-json\/wp\/v2\/product\/20984"}],"collection":[{"href":"https:\/\/skard.ru\/en\/wp-json\/wp\/v2\/product"}],"about":[{"href":"https:\/\/skard.ru\/en\/wp-json\/wp\/v2\/types\/product"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/skard.ru\/en\/wp-json\/wp\/v2\/media\/20986"}],"wp:attachment":[{"href":"https:\/\/skard.ru\/en\/wp-json\/wp\/v2\/media?parent=20984"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}